Question:

What are the techniques used to extract protein through cell lysis?  

The Protein Man Says:

Before a protein sample can be isolated and identified by electrophoresis and Western blotting, the proteins must be separated from component cell parts. This means cell walls and membranes need to be broken apart, or lysed. But lysing techniques should be chosen carefully, since overly aggressive activity can degrade the proteins and make genetic samples difficult to reproduce. Below are a few of the most common and trusted cell lysis methods.  

cell lysis, protein extractionSonication  

Sonication involves inserting a tip into a test tube or eppendorf and sending a high intensity sound wave throughout the sample to disrupt cell walls and shatter tissues. Sonication is easy, and it can be applied to samples of almost any size, but it should be used with care, since this method may cause proteins to overheat and denature (breakdown).  We recommend using multiple, short sonic bursts as opposed to one long burst.  All sonications should be performed on ice and the samples allowed to rest and chill between bursts.  

Liquid Nitrogen Grinding  

Using this method, researchers blend protein samples with liquid nitrogen until they freeze and become brittle. The samples can then be ground with a mortar and pestle. Grinding involves low risk to the integrity of the proteins, but liquid nitrogen can be dangerous. Grinding in liquid nitrogen is a great technique for difficult samples, such as plant and fungi samples.  

Bead Beaters  

This technique involves combining a cell sample with tiny beads in a bowl, which is then mechanically agitated in order to break the cells apart. To avoid overheating the sample, this should be done in a cold environment and the sample should be allowed to rest and cool between beating cycles.  

Buffers  

The simplest, but also the most expensive way to lyse cells and tissues is by using a specific lysis buffer. The lysis buffers are designed to break open cells and tissues chemically.  A large selection of buffers are available ranging from mild lysis buffers to strong, chaotropic, denaturing buffers. The lysis buffers use a combination of buffering agents, salts, detergents, reducing agents, chaotropes and lytic enzymes to release proteins. The use of chemical lysis can also be combined with the above mechanical lysis techniques to improve extraction of proteins.

For a review of the lysis buffers available from G-Biosciences, including non denaturing, denaturing, RIPA and inclusion body lysis buffers, download our Sample Preparation Handbook.  

Important!

Don’t forget that with all these techniques designed to release your protein of interest, the endogenous cellular proteases are also released. So don’t forget to ALWAYS use a Protease Inhibitor Cocktail.  Check back for more information on protease inhibition!

Topics: Protein Extraction

Want more Protein Man blogs?

Purification_resins
Ellyn Daugherty's Biotechnology: Science for the New Millennium

CB™ PROTEIN ASSAY: A Bradford Protein Assay

CB Protein Assay Graph

An improved Coomassie Dye based protein assay based on the Bradford Protein Assay. This assay is suitable for the simple and rapid estimation of protein concentration. This assay is based on a single Coomassie dye based reagent. The binding of protein to the dye results in a change of color from brown to blue. The change in color density is proportional to protein concentration. Protein estimation can be performed using as little as 0.5µg protein.

Features

  • Sensitivity: Linear responses over the range of 0.5µg-50µg protein
  • Flexible Protocols: Suitable for tube or Titer plate assays
  • Ready to use assay reagents and no preparation required
  • Long shelf life, stable for 12 months